PWR8VDC 8 Port Variable DC Power Controller FW Version: V1.1.0 =================================== System Information Commands ?/HELP Print Help Information STATUS Print System Status And Port Status GETSENSORCFG xx Print Sensor Configuration Information xx = 0 All Event, 1 Event1, 2 Event2, 3 Event3 ELESTA Print All Outputs Electricity Level Inf ormation FWVERSION Print FW Version And GUI Version =================================== System Control Commands DEVICENAME:xx Set Device Name To xx PON/POFF Set System Power ON Or OFF STANDBYMODE xx Set The System Standby Mode To xx xx = 0 All_Standby_Mode, 1 Sleep_Mode KEY ON/OFF Set System Key Control ON Or OFF RELAY ON/OFF Set Relay Switch Key Control ON Or OFF SELECTKEY ON/OFF Set Voltage Select Key Control ON Or OF F RESET Reset System To Default Setting(Type "Y es" To Confirm, "No" To Discard) REBOOT Set System Reboot And Apply New Config! !! RESTA Set System Restart SAFEMODE xx Set The System Safe Mode To xx When Ove rloaded xx = 0 Outlet_Shutdown, 1 System_Shutdo wn, 2 Auto_Retry OVERLOADRETRYCNT xx Set The System Retry Number To xx When Overloaded(Default: 1) xx = 1 : 3 OVERLOADRETRYTIME xx Set The System Retry Delay Time To xxmi ns When Overloaded(Default: 3mins) xx = 1 : 10 RELAYMODE xx Set The System Relay Mode To xx xx = 0 Dry_Contact, 1 Push_Button RELAYVOLTAGE xx Set The System Relay Toggle Voltage To xx xx = 0 Low_Voltage, 1 High_Voltage BEEPERTIME xx Set The Buzzer Sound Time To xxs When A larming(Default: 10 Second) xx = 0 : 9999 OUTLETTIMEON xx:yy Set Outlet xx Power_ON Delay To yys xx = 1 Outlet1, 2 Outlet2, 3 Outlet3, 4 Outlet4, 5 Outlet5, 6 Outlet6, 7 Outlet7, 8 Outlet8 yy = 0 : 9999 OUTLETTIMEOFF xx:yy Set Outlet xx Power_OFF Delay To yys xx = 1 Outlet1, 2 Outlet2, 3 Outlet3, 4 Outlet4, 5 Outlet5, 6 Outlet6, 7 Outlet7, 8 Outlet8 yy = 0 : 9999 OUTLETELERESET xx:yy Set Outlet xx Electrical Work Reset Dur ation To yys(Default: 10 Second) xx = 1 Outlet1, 2 Outlet2, 3 Outlet3, 4 Outlet4, 5 Outlet5, 6 Outlet6, 7 Outlet7, 8 Outlet8 yy = 0 : 9999 ALLOUT ON/OFF Set All Outlets ON/OFF OUTLET xx ON/OFF Set Outlet xx ON/OFF xx = 1 Outlet1, 2 Outlet2, 3 Outlet3, 4 Outlet4, 5 Outlet5, 6 Outlet6, 7 Outlet7, 8 Outlet8 ALLVOLT xx Set All Outlets Voltage Status xx xx = 5 5V, 9 9V, 12 12V, 18 18V, 24 24V OUTVOLT xx:yy Set Outlet xx Voltage Status yyV xx = 1 Outlet1, 2 Outlet2, 3 Outlet3, 4 Outlet4, 5 Outlet5, 6 Outlet6, 7 Outlet7, 8 Outlet8 yy = 5 5V, 9 9V, 12 12V, 18 18V, 24 24V VOLTOFFSET xx:yy Set Outlet xx Voltage Offset To yy xx = 1 Outlet1, 2 Outlet2, 3 Outlet3, 4 Outlet4, 5 Outlet5, 6 Outlet6, 7 Outlet7, 8 Outlet8 yy = 0-20 depend on different voltage PLIMIT xx Set Power Limit Mode To xx xx = 0 8x30W, 1 4x36W & 4x30W, 2 8x36W & USB OFF ALLUSB ON/OFF Set All USB ON/OFF USB xx ON/OFF Set USB xx ON/OFF xx = 1 Outlet1, 2 Outlet2, 3 Outlet3, 4 Outlet4, 5 Outlet5, 6 Outlet6, 7 Outlet7, 8 Outlet8 7SEG ON/OFF Set 7-Segment Display ON/OFF RSALLOUTELE Clean Up All Outlets Electrical Work RSOUTELE xx Clean Up The Outlet xx Electrical Work xx = 1 Outlet1, 2 Outlet2, 3 Outlet3, 4 Outlet4, 5 Outlet5, 6 Outlet6, 7 Outlet7, 8 Outlet8 SYSTIME Get The Time For The System RESYSTIME yyyy-mm-dd;hh:mm:ss Set The Time For The System yyyy = Year, mm = Month, dd = Day, hh = Hour, mm = Minutes, ss = Seconds =================================== RS232 Control Commands RS232OUT y:z:c:a Send y Type Of Command a With Baud Rate z, Parity c To Output y=a: ASCII y=h: HEX z=1: 2400 z=2: 4800 z=3: 9600 z=4: 19200 z=5: 38400 z=6: 57600(Default) z=7: 115200 c=1: None c=2: Even c=3: Odd a=RS232 Command RS232BAUD z Set RS232 Baud Rate To xx z = 1 - 2400, 2 - 4800, 3 - 9600, 4 - 1 9200, 5 - 38400, 6 - 57600(Default), 7 - 115200 =================================== SENSOR Control Commands SENSOR1/SENSOR2 POWER xx Set Sensor1/Sensor2 Power To xx xx = 0 OFF, 1 ON SENSOR1/SENSOR2 PROTOCOLS xx Set Sensor1/Sensor2 Protocols To xx xx = 1 1-wire(wiring2,3,6), 2 I2C(wirin g2,3,7,8), 3 Modbus-RTU-RS485(wiring1,2,4,5), 4 Door(wiring2,6), 5 Relay Switch( wiring1,2,6) SENSOR1/SENSOR2 TYPE xx Set Sensor1/Sensor2 Type To xx xx = 1 Temperature, 2 Humidity, 3 Temperature And Humidity, 4 Air Pressure, 5 Other Data, 6 Normally Open, 7 Normally Close SENSOR1/SENSOR2 ADDRESS xx Set Sensor1/Sensor2 Data Address To xx xx = 00 : FF or 0000 : FFFF SENSOR1/SENSOR2 VALUEMAX xx Set Sensor1/Sensor2 Max Value To xx xx = -9999 : 9999 SENSOR1/SENSOR2 VALUEMIN xx Set Sensor1/Sensor2 Min Value To xx xx = -9999 : 9999 SENSOR1/SENSOR2 UNIT xx Set Sensor1/Sensor2 Unit Value To xx xx = 1 ▒▒, 2 %RH, 3 hPa SENSOR1/SENSOR2 BEEPER ON/OFF Set Sensor1/Sensor2 Beeper ON/OFF SENSOR1/SENSOR2 OUTLETMODE xx:yy:zz Set Event xx Outlet yy Response Sensor1/Sensor2 Mode To zz xx = 1 Event1, 2 Event2, 3 Event3 yy = 1 Outlet1, 2 Outlet2, 3 Outlet3, 4 Outlet4, 5 Outlet5, 6 Outlet6, 7 Outlet7, 8 Outlet8 zz = 1 NoAction, 2 Power ON, 3 Power OFF, 4 Restart SENSOR1/SENSOR2 OUTLETTRIGGER xx:yy:zz Set Event xx Outlet yy Response Sensor1/Sensor2 Trigger To zz xx = 1 Event1, 2 Event2, 3 Event3 yy = 1 Outlet1, 2 Outlet2, 3 Outlet3, 4 Outlet4, 5 Outlet5, 6 Outlet6, 7 Outlet7, 8 Outlet8 zz = 1 No Trigger, 2 Max Trigger, 3 Min Trigger, 4 Min-Max, 5 ON, 6 OFF SENSOR1/SENSOR2 OUTLETDELAY xx:yy:zz Set Event xx Outlet yy Response Sensor1/Sensor2 Delay To zzs xx = 1 Event1, 2 Event2, 3 Event3 yy = 1 Outlet1, 2 Outlet2, 3 Outlet3, 4 Outlet4, 5 Outlet5, 6 Outlet6, 7 Outlet7, 8 Outlet8 zz = 0 : 9999 GET SENSOR1/SENSOR2 CURRENT Get Sensor1/Sensor2 Current Value SENSOR1/SENSOR2 MSADDRESS xx Set Sensor1/Sensor2 Modbus Slave Station Address To xx xx = 00 : FF SENSOR1/SENSOR2 MFUNCCODE xx Set Sensor1/Sensor2 Modbus Function Code To xx xx = 03 or 04 ================================== Network Control Commands NET TCP/IP ENABLE xx Set TCP/IP xx Enalbe(Only One Can Be Enabled) xx = 1 TCP/IP1, 2 TCP/IP2 NET TCP/IP1 DHCP ON/OFF Set TCP/IP1 Auto IP(DHCP) ON Or OFF NET TCP/IP1 IP xxx.xxx.xxx.xxx Set TCP/IP1 IP Address NET TCP/IP1 GW xxx.xxx.xxx.xxx Set TCP/IP1 Gateway Address NET TCP/IP1 SM xxx.xxx.xxx.xxx Set TCP/IP1 Subnet Mask Address NET TCP/IP2 DHCP ON/OFF Set TCP/IP2 Auto IP(DHCP) ON Or OFF NET TCP/IP2 IP xxx.xxx.xxx.xxx Set TCP/IP2 IP Address NET TCP/IP2 GW xxx.xxx.xxx.xxx Set TCP/IP2 Gateway Address NET TCP/IP2 SM xxx.xxx.xxx.xxx Set TCP/IP2 Subnet Mask Address NET RB Set Network Reboot And Apply New Config NET MDNS ON/OFF Set mDNS ON/OFF ====================================================================================================